La imagen puede ser una representación.
Consulte las especificaciones para obtener detalles del producto.
S-80850CLUA-B7BT2U

S-80850CLUA-B7BT2U

Product Overview

Category

S-80850CLUA-B7BT2U belongs to the category of integrated circuits (ICs).

Use

This product is commonly used in electronic devices for voltage detection and reset functions.

Characteristics

  • Voltage detection range: 1.6V to 6.0V
  • Accuracy: ±2%
  • Low supply current: 1.0μA (typ.)
  • Small package size: SOT-89-5
  • RoHS compliant

Package

The S-80850CLUA-B7BT2U is packaged in a small outline transistor (SOT) package, specifically SOT-89-5. This package provides excellent thermal performance and ease of handling during assembly.

Essence

The essence of S-80850CLUA-B7BT2U lies in its ability to accurately detect voltage levels within a specified range and provide a reset signal when necessary.

Packaging/Quantity

This product is typically available in reels containing 3,000 units per reel.

Specifications

  • Supply voltage range: 1.6V to 6.0V
  • Detection voltage options: 2.0V, 2.2V, 2.3V, 2.4V, 2.5V, 2.6V, 2.7V, 2.8V, 2.9V, 3.0V, 3.1V, 3.2V, 3.3V, 3.4V, 3.5V, 3.6V, 3.7V, 3.8V, 3.9V, 4.0V, 4.1V, 4.2V, 4.3V, 4.4V, 4.5V, 4.6V, 4.7V, 4.8V, 4.9V, 5.0V, 5.1V, 5.2V, 5.3V, 5.4V, 5.5V, 5.6V, 5.7V, 5.8V, 5.9V
  • Operating temperature range: -40°C to +85°C

Detailed Pin Configuration

The S-80850CLUA-B7BT2U has the following pin configuration:

  1. VDD (Supply Voltage)
  2. GND (Ground)
  3. RESET (Reset Output)
  4. VOUT (Voltage Detection Output)
  5. VIN (Voltage Input)

Functional Features

Voltage Detection

The S-80850CLUA-B7BT2U can accurately detect voltage levels within the specified range. It provides a reset signal when the input voltage falls below the detection threshold.

Reset Function

When the input voltage drops below the detection threshold, the RESET pin becomes active, signaling the need for a system reset.

Low Power Consumption

With a supply current of only 1.0μA, this IC ensures minimal power consumption, making it suitable for battery-powered applications.

Advantages and Disadvantages

Advantages

  • Wide voltage detection range
  • High accuracy
  • Low power consumption
  • Small package size for space-constrained designs
  • RoHS compliant

Disadvantages

  • Limited number of available detection voltage options

Working Principles

The S-80850CLUA-B7BT2U operates by comparing the input voltage with the selected detection voltage. When the input voltage falls below the detection threshold, the reset output is activated, triggering a system reset.

Detailed Application Field Plans

The S-80850CLUA-B7BT2U is widely used in various electronic devices that require voltage monitoring and reset functionality. Some common application fields include:

  1. Battery-powered devices: This IC ensures proper system reset when the battery voltage drops below a certain level, preventing data corruption or malfunction.
  2. Microcontrollers and microprocessors: It provides a reliable reset signal to ensure proper initialization of these components during power-up or voltage fluctuations.
  3. Industrial control systems: The S-80850CLUA-B7BT2U helps maintain stable operation by monitoring critical voltage levels and initiating resets if necessary.

Detailed and Complete Alternative Models

  1. S-80850CLY-B7BT2U
  2. S-80850CNMC-B7JT2U
  3. S-80850CNNC-B7JT2U
  4. S-80850CPNB-B7KT2U
  5. S-80850CPNC-B7KT2U

These alternative models offer similar voltage detection and reset functions, catering to different application requirements.

*Note: The above content meets the required

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de S-80850CLUA-B7BT2U en soluciones técnicas

Sure! Here are 10 common questions and answers related to the application of S-80850CLUA-B7BT2U in technical solutions:

  1. Question: What is the purpose of S-80850CLUA-B7BT2U?
    Answer: S-80850CLUA-B7BT2U is a voltage detector IC used for monitoring power supply voltages in various technical applications.

  2. Question: What is the operating voltage range of S-80850CLUA-B7BT2U?
    Answer: The operating voltage range of S-80850CLUA-B7BT2U is typically between 1.6V and 6.0V.

  3. Question: How does S-80850CLUA-B7BT2U detect voltage levels?
    Answer: S-80850CLUA-B7BT2U uses a built-in voltage reference and comparator circuit to detect voltage levels above or below a specified threshold.

  4. Question: Can S-80850CLUA-B7BT2U be used in battery-powered devices?
    Answer: Yes, S-80850CLUA-B7BT2U can be used in battery-powered devices as it operates within a wide voltage range suitable for such applications.

  5. Question: What is the output configuration of S-80850CLUA-B7BT2U?
    Answer: S-80850CLUA-B7BT2U provides an open-drain output, which requires an external pull-up resistor for proper operation.

  6. Question: Is S-80850CLUA-B7BT2U capable of providing overvoltage protection?
    Answer: No, S-80850CLUA-B7BT2U is not designed for overvoltage protection. It primarily serves as a voltage monitoring device.

  7. Question: Can S-80850CLUA-B7BT2U be used in automotive applications?
    Answer: Yes, S-80850CLUA-B7BT2U is suitable for automotive applications as it can withstand the required temperature and voltage ranges.

  8. Question: What is the typical quiescent current consumption of S-80850CLUA-B7BT2U?
    Answer: The typical quiescent current consumption of S-80850CLUA-B7BT2U is very low, usually around 1.0µA.

  9. Question: Does S-80850CLUA-B7BT2U have any built-in hysteresis?
    Answer: Yes, S-80850CLUA-B7BT2U incorporates a built-in hysteresis feature to prevent output oscillation near the threshold voltage.

  10. Question: Can multiple S-80850CLUA-B7BT2U devices be connected in parallel?
    Answer: Yes, multiple S-80850CLUA-B7BT2U devices can be connected in parallel to monitor different voltage levels simultaneously.

Please note that these answers are general and may vary depending on the specific application and requirements.