S-80859CLUA-B7KT2U belongs to the category of integrated circuits (ICs).
This product is commonly used in electronic devices for voltage detection and reset functions.
The S-80859CLUA-B7KT2U is packaged in a SOT-89-5 package. Each package contains one unit of the IC.
The essence of S-80859CLUA-B7KT2U lies in its ability to accurately detect voltage levels within a specified range and provide a reset signal when necessary.
The S-80859CLUA-B7KT2U has five pins arranged as follows:
```
| | --| |-- |____| ```
Pin 1: GND (Ground) Pin 2: VDD (Supply Voltage) Pin 3: RESET (Output) Pin 4: N/C (No Connection) Pin 5: VIN (Voltage Input)
The S-80859CLUA-B7KT2U operates by comparing the input voltage (VIN) with an internal reference voltage. When the input voltage falls below the detection threshold, the IC generates a reset signal on the RESET pin. This signal remains active for a specified delay period, allowing the system to perform necessary actions during this time. Once the input voltage rises above the threshold, the reset signal is deactivated.
The S-80859CLUA-B7KT2U finds application in various electronic devices where voltage monitoring and reset functionality are required. Some potential application fields include:
These alternative models offer similar functionality to the S-80859CLUA-B7KT2U, providing options for different package sizes, accuracy requirements, and voltage ranges.
Word count: 550 words
Sure! Here are 10 common questions and answers related to the application of S-80859CLUA-B7KT2U in technical solutions:
1. What is S-80859CLUA-B7KT2U? - S-80859CLUA-B7KT2U is a specific model of integrated circuit (IC) used in technical solutions.
2. What is the purpose of S-80859CLUA-B7KT2U? - The purpose of S-80859CLUA-B7KT2U is to provide voltage monitoring and reset functions in various electronic systems.
3. What voltage range does S-80859CLUA-B7KT2U support? - S-80859CLUA-B7KT2U supports a voltage range of 2.2V to 6.0V.
4. How does S-80859CLUA-B7KT2U monitor voltage? - S-80859CLUA-B7KT2U monitors voltage by comparing the input voltage with a reference voltage, triggering a reset signal when the voltage falls below a certain threshold.
5. Can S-80859CLUA-B7KT2U be used in battery-powered applications? - Yes, S-80859CLUA-B7KT2U can be used in battery-powered applications as it operates within a wide voltage range and has low power consumption.
6. What is the typical operating current of S-80859CLUA-B7KT2U? - The typical operating current of S-80859CLUA-B7KT2U is around 1.0µA.
7. Does S-80859CLUA-B7KT2U have any built-in delay for the reset signal? - Yes, S-80859CLUA-B7KT2U has a built-in delay of approximately 200ms for the reset signal to ensure stability during power-up.
8. Can S-80859CLUA-B7KT2U be used in automotive applications? - Yes, S-80859CLUA-B7KT2U is suitable for automotive applications as it meets the necessary quality and reliability standards.
9. What is the package type of S-80859CLUA-B7KT2U? - S-80859CLUA-B7KT2U comes in a small surface-mount package known as SOT-89.
10. Are there any specific precautions to consider when using S-80859CLUA-B7KT2U? - It is recommended to follow the manufacturer's datasheet and application notes for proper usage and handling guidelines of S-80859CLUA-B7KT2U.