La imagen puede ser una representación.
Consulte las especificaciones para obtener detalles del producto.
DS1816-10+T&R

DS1816-10+T&R

Product Overview

Category: Integrated Circuits
Use: Voltage Supervisors
Characteristics: High precision, low power consumption
Package: Tape and Reel (T&R)
Essence: Monitoring and controlling voltage levels
Packaging/Quantity: 2500 units per reel

Specifications

  • Supply Voltage: 1.8V to 5.5V
  • Operating Temperature Range: -40°C to +85°C
  • Output Type: Active Low
  • Threshold Voltage Accuracy: ±1.5%
  • Quiescent Current: 2µA (typical)
  • Power-On Reset Delay: 100ms (typical)

Detailed Pin Configuration

The DS1816-10+T&R has the following pin configuration:

  1. GND (Ground)
  2. VCC (Supply Voltage)
  3. RESET (Active Low Reset Output)
  4. MR (Manual Reset Input)

Functional Features

  • Monitors supply voltage and provides a reset signal when it falls below a specified threshold.
  • Offers manual reset capability for system debugging or initialization.
  • Provides accurate voltage monitoring with low power consumption.
  • Ensures reliable system operation by preventing erratic behavior during power-up and power-down.

Advantages and Disadvantages

Advantages: - High precision voltage monitoring - Low quiescent current - Wide operating voltage range - Compact package size - Easy integration into various electronic systems

Disadvantages: - Active low output may require additional level shifting circuitry in certain applications. - Limited number of alternative models available in the market.

Working Principles

The DS1816-10+T&R operates by continuously monitoring the supply voltage using an internal voltage reference and comparator. When the voltage drops below the preset threshold, the active low reset output is asserted, indicating a power failure or voltage drop. The manual reset input allows the system to be reset externally, providing flexibility during debugging or initialization.

Detailed Application Field Plans

The DS1816-10+T&R is widely used in various applications where reliable voltage monitoring is critical. Some of the common application fields include:

  1. Embedded Systems: Ensures proper operation and prevents data corruption in microcontrollers, DSPs, and FPGAs.
  2. Power Management: Protects sensitive electronic components from voltage fluctuations and ensures safe shutdown during power loss.
  3. Industrial Automation: Monitors power supply integrity in PLCs, motor control systems, and industrial sensors.
  4. Automotive Electronics: Provides voltage supervision for automotive ECUs, infotainment systems, and safety modules.
  5. Medical Devices: Ensures stable power supply for critical medical equipment, such as patient monitors and diagnostic devices.

Detailed and Complete Alternative Models

  1. DS1816-15+T&R: Similar to DS1816-10+T&R but with a higher threshold voltage accuracy of ±1.0%.
  2. DS1816-12+T&R: Similar to DS1816-10+T&R but with a lower quiescent current of 1µA (typical).
  3. DS1816-08+T&R: Similar to DS1816-10+T&R but with a wider operating temperature range of -55°C to +125°C.

These alternative models offer different specifications to cater to specific application requirements.

Word count: 345 words

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de DS1816-10+T&R en soluciones técnicas

Sure! Here are 10 common questions and answers related to the application of DS1816-10+T&R in technical solutions:

  1. Q: What is DS1816-10+T&R? A: DS1816-10+T&R is a specific model of a digital temperature sensor and thermostat manufactured by Maxim Integrated.

  2. Q: What is the operating temperature range of DS1816-10+T&R? A: The operating temperature range of DS1816-10+T&R is -55°C to +125°C.

  3. Q: How does DS1816-10+T&R communicate with other devices? A: DS1816-10+T&R communicates using a 1-Wire interface, which allows it to be connected to microcontrollers or other compatible devices.

  4. Q: Can DS1816-10+T&R be used for temperature monitoring in industrial applications? A: Yes, DS1816-10+T&R is suitable for temperature monitoring in various industrial applications due to its wide operating temperature range.

  5. Q: Does DS1816-10+T&R require external calibration? A: No, DS1816-10+T&R is factory calibrated and does not require any external calibration.

  6. Q: Can DS1816-10+T&R be powered directly from the 1-Wire bus? A: Yes, DS1816-10+T&R can be powered directly from the 1-Wire bus, eliminating the need for an additional power supply.

  7. Q: Is DS1816-10+T&R compatible with popular microcontroller platforms like Arduino? A: Yes, DS1816-10+T&R is compatible with popular microcontroller platforms like Arduino, as long as they support the 1-Wire protocol.

  8. Q: Can DS1816-10+T&R be used for temperature control in HVAC systems? A: Yes, DS1816-10+T&R can be used for temperature control in HVAC (Heating, Ventilation, and Air Conditioning) systems.

  9. Q: Does DS1816-10+T&R provide any digital output signals? A: Yes, DS1816-10+T&R provides a digital output signal that can be used to trigger actions based on temperature thresholds.

  10. Q: Are there any specific application notes or documentation available for DS1816-10+T&R? A: Yes, Maxim Integrated provides application notes and documentation on their website that provide detailed information on using DS1816-10+T&R in various technical solutions.

Please note that the answers provided here are general and may vary depending on the specific requirements and use cases of DS1816-10+T&R in different applications.