P51-1000-A-Y-D-20MA-000-000

P51-1000-A-Y-D-20MA-000-000

Category: Electronic Component

Use: This product is a precision pressure sensor designed to measure and monitor pressure in various industrial applications.

Characteristics: The P51-1000-A-Y-D-20MA-000-000 sensor features high accuracy, reliability, and stability. It is designed to withstand harsh environmental conditions and provide precise pressure measurements.

Package: The sensor comes in a compact and durable housing, ensuring protection from external elements. It is designed for easy installation and integration into different systems.

Essence: The essence of the P51-1000-A-Y-D-20MA-000-000 sensor lies in its ability to provide accurate and consistent pressure readings in demanding industrial environments.

Packaging/Quantity: The sensor is typically packaged individually and is available in varying quantities based on customer requirements.

Specifications:

  • Pressure Range: 0-1000 psi
  • Output: 4-20 mA
  • Accuracy: ±0.5% FS
  • Operating Temperature: -40°C to 125°C
  • Supply Voltage: 10-30 VDC

Detailed Pin Configuration:

The sensor has a standard pin configuration with connections for power supply, ground, and output signal. It also includes pins for temperature compensation and calibration.

Functional Features:

  • High precision pressure measurement
  • Robust construction for industrial environments
  • Compatibility with various control systems
  • Long-term stability and reliability

Advantages:

  • Accurate and reliable pressure measurements
  • Suitable for harsh industrial environments
  • Easy integration into existing systems
  • Long-term stability and durability

Disadvantages:

  • Limited pressure range compared to some other sensors
  • Requires proper calibration for optimal performance

Working Principles:

The P51-1000-A-Y-D-20MA-000-000 sensor operates on the principle of piezoresistive technology, where changes in pressure cause a corresponding change in electrical resistance. This change is then converted into a proportional 4-20 mA output signal.

Detailed Application Field Plans:

This sensor is ideal for use in industrial hydraulic systems, pneumatic systems, process control, and automotive applications. Its robust design and high accuracy make it suitable for critical pressure monitoring in various industrial processes.

Detailed and Complete Alternative Models:

  • P51-870-A-A-I12-4.5V-000-000
  • P51-2000-A-A-I36-4.5V-000-000
  • P51-5000-A-A-I36-4.5V-000-000

These alternative models offer different pressure ranges and output options to cater to diverse application requirements.

In conclusion, the P51-1000-A-Y-D-20MA-000-000 precision pressure sensor is a reliable and accurate solution for industrial pressure monitoring needs. Its robust construction, high accuracy, and compatibility with various systems make it a valuable component in industrial applications.

[Word count: 413]

Enumere 10 preguntas y respuestas comunes relacionadas con la aplicación de P51-1000-A-Y-D-20MA-000-000 en soluciones técnicas

Sure, here are 10 common questions and answers related to the application of P51-1000-A-Y-D-20MA-000-000 in technical solutions:

  1. What is the operating range of P51-1000-A-Y-D-20MA-000-000?

    • The operating range of P51-1000-A-Y-D-20MA-000-000 is typically from 0 to 1000 psi.
  2. What is the output signal of P51-1000-A-Y-D-20MA-000-000?

    • The output signal of P51-1000-A-Y-D-20MA-000-000 is a 4-20 mA current loop.
  3. Can P51-1000-A-Y-D-20MA-000-000 be used in high-temperature environments?

    • Yes, P51-1000-A-Y-D-20MA-000-000 is designed to operate in high-temperature environments up to a certain limit.
  4. What is the accuracy of P51-1000-A-Y-D-20MA-000-000?

    • The accuracy of P51-1000-A-Y-D-20MA-000-000 is typically within a certain percentage of the full scale.
  5. Is P51-1000-A-Y-D-20MA-000-000 suitable for use with corrosive media?

    • P51-1000-A-Y-D-20MA-000-000 can be specified with materials suitable for use with corrosive media.
  6. What is the response time of P51-1000-A-Y-D-20MA-000-000?

    • The response time of P51-1000-A-Y-D-20MA-000-000 is typically within a certain range, depending on the application.
  7. Can P51-1000-A-Y-D-20MA-000-000 be used in hazardous areas?

    • Yes, P51-1000-A-Y-D-20MA-000-000 can be specified with intrinsically safe or explosion-proof options for use in hazardous areas.
  8. What is the recommended installation orientation for P51-1000-A-Y-D-20MA-000-000?

    • The recommended installation orientation for P51-1000-A-Y-D-20MA-000-000 is typically with the pressure port facing downward to prevent moisture ingress.
  9. Does P51-1000-A-Y-D-20MA-000-000 require calibration?

    • P51-1000-A-Y-D-20MA-000-000 may require periodic calibration to maintain its accuracy over time.
  10. What is the typical lifespan of P51-1000-A-Y-D-20MA-000-000?

    • The typical lifespan of P51-1000-A-Y-D-20MA-000-000 is dependent on the operating conditions and usage, but it is designed for long-term reliability.

I hope these questions and answers are helpful for your technical solutions! Let me know if you need further assistance.